Bio-capacitance probe system

National Research Council of Canada (NRC)
canadabuys Posted: July 29, 2026

WHAT: Acquisition of a new four-probe system for real-time measurement of bio-capacitance for cell culture in bioreactors, enabling estimation of viable cell concentration in up to four bioreactors in parallel. Probes must be compatible with various bioreactor types and allow multi-frequency scannin...

Read full summary
Due Date
August 24, 2026
(14 days left)
Solicitation #
26-58103

Actions

Create a free account to analyze this opportunity, get daily notifications, and win more bids with Narwin.ai

Documents

26-58103_qa_02.pdf
PDF • 322.1 KB
26-58103_qa_01.pdf
PDF • 309.0 KB
26-58103_npp_en.pdf
PDF • 287.6 KB
26-58103_rfp_en.pdf
PDF • 987.5 KB

Description

Acquisition of a new four-probe system enabling real-time measurement of bio-capacitance for cell culture in bioreactors, for up to four bioreactors in parallel. This system will enable real-time estimation of viable cell concentration in those bioreactors. Measuring bio-capacitance at multiple frequencies, at regular intervals, in order to obtain the capacitance distribution spectrum of the cells, thereby enabling the real-time calculation of other critical cell culture parameters such as cell size, internal cell conductivity, and critical frequency. The probes to be acquired under this procurement must be compatible with the different types of bioreactors used by the team. In addition, the selected bio-capacitance probes must allow multi-frequency scanning for real-time determination of the intrinsic dielectric properties of the cells through analysis of the ß-dispersion of the signal using the Cole–Cole a model. Finally, the generated data must be capable of being captured in real time both by the control and data acquisition system via OPC-UA communication, and via 4–20 mA communication to enable integration of the probe directly into a control loop.

Additional Information

Amendment Number

002

Contact Info Address Line

6100 AVENUE ROYALMOUNT (PORTES 6 & 7)

Contact Info City

MONTREAL

Contact Country

Canada

Contact Info Email

Contact Info Name

Daniel Rusthoven

Contact Info Phone

+13435429384

Contact Info Postal Code

H4P 2R2

Contact Info Province

Quebec

Contracting Entity Name

National Research Council of Canada (NRC)

Created

August 10, 2026

Is Public

true

Organization Address City

Ottawa

Organization Country

Canada

Organization Address Line

1200 Montreal Road

Organization Address Postal Code

K1A 0R6

Organization Address Province

ON

Procurement Category

*GD

Procurement Method

Competitive - Open bidding

Reference Number

cb-483-56366637

Regions Of Opportunity

*Canada

Selection Criteria

Lowest Price

Source

canadabuys

Source Record ID

cb-483-56366637_002

Source System

canadabuys

Status

open

Status En

Open

Summary Updated At

August 10, 2026

Tender Closing Date

August 24, 2026

Last Updated

August 10, 2026

Frequently Asked Questions

When is the proposal submission deadline?

The proposal submission deadline is August 24, 2026 (14 days left).

Where can I submit a proposal or get solicitation documents?

You can access the full solicitation documents and submit your proposal at the official source:

Visit Official Source

AI Summary

WHAT: Acquisition of a new four-probe system for real-time measurement of bio-capacitance for cell culture in bioreactors, enabling estimation of viable cell concentration in up to four bioreactors in parallel. Probes must be compatible with various bioreactor types and allow multi-frequency scanning for real-time determination of intrinsic dielectric properties of cells. Data must be captured in real time via OPC-UA communication and 4–20 mA communication.

BUYER: National Research Council of Canada (NRC), Ottawa, ON, Canada. Contact: Daniel Rusthoven ([email protected])

GEOGRAPHY: Canada

DATES: Posted: 2026-07-29; Due: 2026-08-24

INDUSTRY/DOMAIN: Laboratory and scientific equipment

MANDATORY QUALS: Probes must be compatible with different types of bioreactors and support multi-frequency scanning.

SPECS & CAPABILITIES: Must enable real-time calculation of cell culture parameters such as cell size and internal cell conductivity using the Cole–Cole a model.

Narwin.ai is a great way to find government contracts and opportunities. Disclaimer: This bid/tender/opportunity information is presented as is and may be incorrect at times. Please read the tender documents carefully before finalizing bids. We do not accept any responsibility and cannot be held legally liable for any inaccuracies.